MSP430F5438A interrupt system implementation

1. The MSP430F5438A has three timers: TA0, TA1, and TB0.

2. CCR0 uses an interrupt vector alone and has the highest priority. Other CCR1-CCR5 use a common interrupt vector. 3

3, interrupt vector:

#define TIMER1_A1_VECTOR (48 * 2u) /* 0xFFE0 TImer1_A3 CCR1-2, TA1 */

#define TIMER1_A0_VECTOR (49 * 2u) /* 0xFFE2 TImer1_A3 CCR0 */

#define TIMER0_A1_VECTOR (53 * 2u) /* 0xFFEA Timer0_A5 CCR1-4, TA0 */

#define TIMER0_A0_VECTOR (54 * 2u) /* 0xFFEC Timer0_A5 CCR0 */

#define TIMER0_B1_VECTOR (59 * 2u) /* 0xFFF6 Timer0_B7 CCR1-6, TB */

#define TIMER0_B0_VECTOR (60 * 2u) /* 0xFFF8 Timer0_B7 CCR0 */

4, can be referenced when writing code

Interrupt vector name

Interrupt vector

Timer

meaning

Operating register

TIMER1_A1_VECTOR

0xFFE0

TA1

TA1CCR1-2, TA1IFG

Compare match channels 1 and 2, overflow interrupt

TA1CCTL1, TA1CCR1

TA1CCTL2, TA1CCR2

TA1CTL (overflow interrupt)

TIMER1_A0_VECTOR

0xFFE2

TA1

TA1CCR0

Compare Match Channel 0

TA1CCTL0, TA1CCR0

TIMER0_A1_VECTOR

0xFFEA

TA0

TA0CCR1-4, TA0IFG

Compare Match Channels 1 to 4

Overflow interrupt

TA0CCTL1,TA0CCR1

TA0CCTL2,TA0CCR2

TA0CCTL3,TA0CCR3

TA0CCTL4,TA0CCR4

TA0CTL (overflow interrupt)

TIMER0_A0_VECTOR

0xFFEC

TA0

TA0CCR0

Compare Match Channel 0

TA0CCTL0,TA0CCR0

TIMER0_B1_VECTOR

0xFFF6

TB

TBCCR1-6, TBIFG

Compare Match Channels 1 to 6

Overflow interrupt


TIMER0_B0_VECTOR