Model NO.: 15kv single core cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE
Model: Mv Cable
Brand: Jytop
Color: Black,Red,Yellow,Blue,Brown,Green
Certificate: Ce, ISO 9001
Business Type: Manufacturer
Key Word: 15kv Cable
Key Word 2: Mv Cables
Key Word 3: 1X120mm
Key Word 4: Single Core Cable
Trademark: JYTOP
Transport Package: Packed in Reels
Specification: any Third party Pre-shipment inspection
Origin: Zhengzhou, China
HS Code: 8544601200
Model NO.: 15kv single core cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE
Model: Mv Cable
Brand: Jytop
Color: Black,Red,Yellow,Blue,Brown,Green
Certificate: Ce, ISO 9001
Business Type: Manufacturer
Key Word: 15kv Cable
Key Word 2: Mv Cables
Key Word 3: 1X120mm
Key Word 4: Single Core Cable
Trademark: JYTOP
Transport Package: Packed in Reels
Specification: any Third party Pre-shipment inspection
Origin: Zhengzhou, China
HS Code: 8544601200
Company Description1. CE, ISO 9001 Certificaes
2. More than 23 years experiences
3. Professional Manufacturer with Factory located in Henan Province.
4. Quick response and fast delivery.
5. Serve everyone with heart and soul.
Medium voltage cable 15kv cable single core 1x120mm swa cable Factory
1.Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC inner covering as armoring bedding, galvanized steel wire
armored, PVC or PE outer sheath.
If you need other type of medium voltage cable, please visit our home page or contact us for more information.
Â
Â
2. Operating Characteristics
Rated voltage U0/U(Um): 8.7/15(17.5)kV
Â
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed; U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Â
Max. permissible continuous operating temperature of conductor: 90 °C
Â
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:Â
For single core cable: not less than 15 times of the diameter of cableÂ
For three core cable: not less than 12 times of the diameter of cable Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC inner covering as armoring bedding, galvanized steel wire
armored, PVC or PE outer sheath.
If you need other type of medium voltage cable, please visit our home page or contact us for more information.
Â
 Chinese Type |
 Description |
Core qty | Conductors range |
 YJV32 |
Copper conductor, XLPE insulation, Steel Wire Armored, PVC outer sheath Power Cable | Â 1 or 3 |
25~800mm2 |
 YJV33 |
Copper conductor, XLPE insulation, Steel Wire Armored, PE outer sheath Power Cable | Â 1 or 3 |
 25~800mm2 |
ZA-YJV32 ZB-YJV32 ZC-YJV32 |
 Copper conductor, XLPE insulation, Steel Wire Armored flame-retardant Power Cable |
 1 or 3 |
 25~800mm2 |
WDZA-YJY33 WDZB-YJY33 WDZC-YJY33 |
Copper conductor, XLPE insulation, Steel Wire Armored Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable | Â 1 or 3 |
 25~800mm2 |
2. Operating Characteristics
Rated voltage U0/U(Um): 8.7/15(17.5)kV
Â
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed; U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Â
Max. permissible continuous operating temperature of conductor: 90 °C
Â
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:Â
For single core cable: not less than 15 times of the diameter of cableÂ
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non- magnetic.
Â
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel, in cable trench, or direct in ground, able to bear external mechanical force and certain pulling force.
Â
4. Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008
Â
We can produce above cables according to popular international standards such as ASTM,BS,DIN,NF &AS/NZ also.
Â
 Â
5. Main technical data for 15kv cable, medium voltage cable


 5. Main technical data for 15kv cable, medium voltage cable



Â
Â
Â
5.3 Main technical data of 8.7/15KV Single core, Aluminum conductor, XLPE insulated, copper wire screened, galvanized steel wire armored and PVC or PE sheath cable
CABLE CONSTRUCTION: 8.7/15KV AL/XLPE/CWS/SWA//PVC or PE
Â
5.1 Main technical data of 8.7/15KV, Single core, Aluminum conductor, XLPE insulated, galvanized steel wire armored and PVC or PE sheath cable
CABLE CONSTRUCTION: 8.7/15KV AL/XLPE/SWA/PVC or PEÂ
Â
5.2 Main technical data of 8.7/15KV, Single core, Aluminum conductor, XLPE insulated, pure aluminum wire armored and PVC or PE sheath cable
CABLE CONSTRUCTION: 8.7/15KV AL/XLPE/AWA/PVC or PEÂ
CABLE CONSTRUCTION: 8.7/15KV AL/XLPE/SWA/PVC or PEÂ
  Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Approx. diameter of armoring steel wire(mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km) |
1x25mm2 | 4.5 | 0.12 | 1.6 | 1.8 | 28.2 | 1.20 |
1x35mm2 | 4.5 | 0.12 | 1.6 | 1.9 | 29.4 | 0.868 |
1x50mm2 | 4.5 | 0.12 | 1.6 | 1.9 | 30.5 | 0.641 |
1x70mm2 | 4.5 | 0.12 | 1.6 | 1.9 | 32.2 | 0.443 |
1x95mm2 | 4.5 | 0.12 | 2.0 | 2.0 | 34.8 | 0.320 |
1x120mm2 | 4.5 | 0.12 | 2.0 | 2.1 | 36.4 | 0.253 |
1x150mm2 | 4.5 | 0.12 | 2.0 | 2.1 | 38.0 | 0.206 |
1x185mm2 | 4.5 | 0.12 | 2.0 | 2.2 | 39.6 | 0.164 |
1x240mm2 | 4.5 | 0.12 | 2.0 | 2.3 | 42.4 | 0.125 |
1x300mm2 | 4.5 | 0.12 | 2.0 | 2.3 | 44.4 | 0.100 |
1x400mm2 | 4.5 | 0.12 | 2.5 | 2.5 | 49.2 | 0.0778 |
1x500mm2 | 4.5 | 0.12 | 2.5 | 2.6 | 53.1 | 0.0605 |
1x630mm2 | 4.5 | 0.12 | 2.5 | 2.7 | 57.1 | 0.0469 |
1x800mm2 | 4.5 | 0.12 | 2.5 | 2.8 | 61.3 | 0.0369 |
5.2 Main technical data of 8.7/15KV, Single core, Aluminum conductor, XLPE insulated, pure aluminum wire armored and PVC or PE sheath cable
CABLE CONSTRUCTION: 8.7/15KV AL/XLPE/AWA/PVC or PEÂ
 Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Approx. diameter of armoring pure aluminum wire(mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km) |
1x25mm2 | 4.5 | 0.12 | 1.6 | 1.8 | 28.2 | 1.20 |
1x35mm2 | 4.5 | 0.12 | 1.6 | 1.9 | 29.4 | 0.868 |
1x50mm2 | 4.5 | 0.12 | 1.6 | 1.9 | 30.5 | 0.641 |
1x70mm2 | 4.5 | 0.12 | 1.6 | 1.9 | 32.2 | 0.443 |
1x95mm2 | 4.5 | 0.12 | 2.0 | 2.0 | 34.8 | 0.320 |
1x120mm2 | 4.5 | 0.12 | 2.0 | 2.1 | 36.4 | 0.253 |
1x150mm2 | 4.5 | 0.12 | 2.0 | 2.1 | 38.0 | 0.206 |
1x185mm2 | 4.5 | 0.12 | 2.0 | 2.2 | 39.6 | 0.164 |
1x240mm2 | 4.5 | 0.12 | 2.0 | 2.3 | 42.4 | 0.125 |
1x300mm2 | 4.5 | 0.12 | 2.0 | 2.3 | 44.4 | 0.100 |
1x400mm2 | 4.5 | 0.12 | 2.5 | 2.5 | 49.2 | 0.0778 |
1x500mm2 | 4.5 | 0.12 | 2.5 | 2.6 | 53.1 | 0.0605 |
1x630mm2 | 4.5 | 0.12 | 2.5 | 2.7 | 57.1 | 0.0469 |
1x800mm2 | 4.5 | 0.12 | 2.5 | 2.8 | 61.3 | 0.0369 |
Â
5.3 Main technical data of 8.7/15KV Single core, Aluminum conductor, XLPE insulated, copper wire screened, galvanized steel wire armored and PVC or PE sheath cable
CABLE CONSTRUCTION: 8.7/15KV AL/XLPE/CWS/SWA//PVC or PE
Â
  Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Nominal diameter of copper wire(mm) |
Approx. diameter of steel wire (mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km)Digital Signage Indoor Digital Signage Indoor,Digital Menu Screen,Digital Menu Boards,Indoor Digital Signage Guangdong Elieken Electronic Technology Co.,Ltd. , https://www.elieken.com |