System Electromagnetic Compatibility Design Technology Based on Switching Power Supply

With the rapid development of electronic technology, electronic devices are also moving toward functional integration and miniaturization, which brings us a lot of convenience, but the electromagnetic coupling between various electronic devices has become an engineer's face. The main problem. The harm of electronic environmental pollution is no less than that of traditional environmental pollution. Electromagnetic pollution has also been put on the agenda as part of environmental pollution. This paper briefly introduces a technical problem and design method that should be paid attention to when designing the whole machine electromagnetic compatibility around the power supply itself.

This article comes from the Jin Shengyang science and technology engineer's manuscript, please indicate the source, thank you!

During normal operation, electronic equipment will withstand various electromagnetic interferences, including mutual interference of its own internal devices, as well as interference from other electronic devices around it, and electromagnetic interference to other surrounding electronic devices. The requirements for electronic equipment in different application environments (home, industrial control, power) are very different. In this respect, reference can be made to the general standard IEC/EN61000-6 series or the corresponding industry requirements.

This kind of electromagnetic interference mainly includes two aspects in the transmission path: one is transmission along the wire harness, which mainly includes transmission along the power port and transmission of the signal port; on the other hand, the transmission is mainly along the space.

Electromagnetic interference:

The power supply must meet the corresponding minimum emission energy requirements in its application environment, otherwise it will interfere with the surrounding environment equipment. The standard IEC/EN61000-6 is divided into industrial environment equipment requirements and residential areas and commercials according to the general type requirements. The emission requirements for district and light industrial environments; for general-purpose products such as power supplies, the electromagnetic interference location at the beginning of the design will be designed in accordance with IEC/EN61000-6-3 or IEC/EN61000-6-4 unless it is a special model.

With the continuous miniaturization of the power supply, the power density continues to increase, and the design of electromagnetic interference for the power supply itself is constantly increasing. MORNSUN currently has not only built-in filters for all AC-DCs, but also for transformer shielding. Power device noise absorption has invested a large amount of design cost to meet the commitment requirements; R2 generation low-power DC-DC products are all designed with six-sided shielding structure to meet the industry CLASS A of EN55022/CISPR 22, EN55011/CISPR 11 Requirements, in line with the level requirements of the basic industry.

Although the power supply itself has invested a lot of design costs and meets the requirements of various indicators, but the power supply in the market is still inevitably subject to electromagnetic interference exceeding the standard; at this time, many design engineers will consider the root cause of the problem In the power supply, this aspect of the understanding is actually a misunderstanding, because the electromagnetic interference conducted disturbance test project, mainly for the power port, then the power port becomes his transmission path, all electromagnetic interference will be reached through the power port Measuring equipment, but the electromagnetic interference detected by the testing equipment, in addition to the power supply itself, the main part also includes the electromagnetic interference generated by other parts of the whole machine, and the electromagnetic interference generated by the resonance of the internal parasitic parameters of the equipment. It will be coupled to the test equipment through the power port. The internal filter of the power supply cannot be used to filter this part of the electromagnetic interference. The power supply application environment is very different. All the power supply design filters are mainly considered to solve their own interference. Filter attenuation Sex and spectrum characteristics should reserve the largest margin as much as possible, but it is not compatible with all applications; then this requires our designers to design the power supply front end, must be designed according to the application circuit recommended by the power supply manufacturer, for example : The problem of EMI exceeding the standard during the application of LH15 product (see the figure below).

System Electromagnetic Compatibility Design Technology Based on Switching Power Supply

The above picture shows the results of the conducted disturbance test of the MORNSUN power supply LH15-10B05. This result complies with the CLASS B requirements of EN55022/CISPR22, and the margin is very sufficient.

System Electromagnetic Compatibility Design Technology Based on Switching Power Supply


The above picture shows that the power supply of MORNSUN power supply LH15-10B05 is applied to a certain brand of products, the whole machine tests the conducted disturbance results, this result can not meet the CLASS B requirements of EN55022/CISPR22, even CLASS A can not meet the requirements, let alone design margin.

Therefore, even if the internal electromagnetic interference design level is higher, the application part must be left in the application process. The specific parameters can refer to the specification of the specific product. MORNSUN's power products will have an application circuit column in the specification, which will describe the indicators on the basis of the application circuit in great detail.

KNLE2-63 Residual Current Circuit Breaker With Over Load Protection

KNLE2-63 TWO FUNCTION : MCB AND RCCB FUNCTIONS

leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage.
leakage breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and short-circuited as wellas infrequent changeover of the line in normal situation. It complies with standard of IEC/EN61009-1 and GB16917.1.


KNLE2-63 Residual Current Circuit Breaker,Residual Current Circuit Breaker with Over Load Protection 1p,Residual Current Circuit Breaker with Over Load Protection 2p

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.zjmannualmotorstarter.com