1. AAC/ACSR/AAAC/Aacsr Overhead Line Conductor

The conductors are used in overhead power line. Overhead conductor covers a serious of conductors such as AAC(All Aluminium Conductor), ACSR(Aluminium Conductor Steel Reinforced ), AACSR (Aluminum Alloy Conductor Steel Reinforced) AAAC(Aluminum Alloy Conductor ), BCC(Bare Copper Conductor), ACS(Aluminium Clad Steel Conductor).

2. AAC Conductor (All Aluminium Conductor)

2.1 AAC Conductor Standard available such as IEC61089, BS215, CSA 61089, ASTM B-231, DIN 48201, etc.

2.2. AAC Conductor is widely used in power transmission lines with various voltage levels. It has good characteristics such as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical textures exist.

2.3. Strands no.: 7 Strands, 19 Strands, 37 Strands, 61Strands, 91 Strands, 127Strands

2.4. Cross-section area: 16~1500 mm2, 4AWG ~ 3000KMCIL

2.5. AAC Conductor insulated with XLPE/PE/PVC can be supplied as per the customers` requirement.



3. ACSR Conductor (Aluminium Conductor Steel Reinforced)

3.1. ACSR Conductor standard available such as IEC61089, BS215, CSA 61089, ASTM B-232, DIN 48204, etc.

3.2. ACSR Conductor is widely used in power transmission lines with various voltage levels. It has good characteristics such as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical textures exist.

3.3. ACSR consists of a galvanized steel core of 1 wire, 7 wires or 19 wires surrounded by concentric layers of aluminium wire. When a conductor with a high current carrying capacity and comparatively low strength is required, special constructions are available with a high aluminium content.

3.4. Protection against Corrosion (Optional)
Grease can be used to the steel core. One or more layers of the aluminium wires can, if required, be supplied partially or fully greased.


4. AAAC Conductor (All Aluminium Alloy Conductor)

4.1. AAAC Conductor standard available such as IEC61089, ASTM B-399, BS3242, CSA60104, DIN 48201, CSA 60104, etc.

4.2. AAAC and AACSR are widely used in power transmission lines with various voltage levels, and also used in power lines across great rivers, heavy ice area, etc. They are of excellent advantages of high strength, large current carrying capacity and good catenaries property as well as wear-resistance, anti-crush and corrosion-proof with simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity.

4.3. Protection against Corrosion (Optional)
Grease can be used to the steel core. One or more layers of the aluminium wires can, if required, be supplied partially or fully greased.


5. AACSR(Aluminium Alloy Steel Reinforced Conductor )
AACSR Conductors according to ASTM, AS, BS, CSA, DIN, IEC, NFC, etc
AACSR is a conductor concentrically stranded of one or more layers of Aluminium -Magnesium -Silicon Alloy wire and steel core. The steel core can be of either single wire or stranded multi wire.

Note: Corrosion protection grease is available according to customer`s requirement.

Certificate available: ISO, CE, SGS, SONCAP, BV, COC etc.

For further information, pls contact us.

CONSTRUCTION
Aluminum 1350-H19 wires, concentrically stranded around steel core. Core wire for ACSR is available with class A, B, or C galvanizing; "aluminized" aluminum coated (AZ); or aluminum - clad - (AW). Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable
Parameter of ACSR conductor
 
Code word
Size (AWG or kcmil)  
Strand- ing (Al/Stl)
 
Diameter(ins.)
Weight per 1000 ft. (Lbs)  
Content (%)
 
Rated strength (Lbs)
Resistance
 /1000 ft.
 
Allowable ampacity+ (Amps)
Individual wire Steel core Complete cable  
Al
 
St
 
Total
 
Al
 
St
DC at
20ºC
AC at
75ºC
Al Stl
Turkey 6 6/1 .0661 .0661 .0661 .198 24 12 36 67.88 32.12 1190 .641 .806 105
Swan 4 6/1 .0834 .0834 .0834 .25 39 18 57 67.87 32.12 1860 .403 .515 140
Swanate 4 7/1 .0772 .103 .103 .257 39 28 67 58.1 41.9 2360 .399 .519 140
Sparrow 2 6/1 .1052 .1052 .1052 .316 62 29 91 67.9 32.1 2850 .254 .332 184
Sparate 2 7/1 .0974 .1298 .1298 .325 62 45 107 58.12 41.88 3460 .251 .338 184
Robin 1 6/1 .1181 .1181 .1181 .354 78 37 115 67.88 32.12 3550 .201 .268 212
Raven 1/0 6/1 .1327 .1327 .1327 .398 99 47 145 67.89 32.11 4380 .159 .217 242
Quail 2/0 6/1 .1489 .1489 .1489 .447 124 59 183 67.88 32.12 5310 .126 .176 276
Pigeon 3/0 6/1 .1672 .1672 .1672 .502 156 74 230 67.87 32.13 6620 .100 .144 315
Penguin 4/0 6/1 .1878 .1878 .1878 .563 197 93 291 67.89 32.12 8350 .0795 .119 357
Waxwing 266.8 18/1 .1217 .1217 .1217 .609 250 39 289 86.43 13.57 6880 .0643 .0787 449
Partridge 266.8 26/7 .1013 .0788 .2363 .642 251 115 367 68.51 31.49 11300 .0637 .0779 475
Ostrich 300 26/7 .1074 .0835 .2506 .68 283 130 412 68.51 31.49 12700 .0567 .0693 492
Merlin 336.4 18/1 .1367 .1367 .1367 .684 315 49 365 86.43 13.57 8680 .0510 .0625 519
 
Linnet 336.4 26/7 .1137 .0885 .2654 .72 317 146 462 68.51 31.49 14100 .0505 .0618 529
Oriole 336.4 30/7 .1059 .1059 .3177 .741 318 209 526 60.35 39.65 17300 .0502 .0613 535
Chickadee 397.5 18/1 .1486 .1486 .1486 .743 373 58 431 86.43 13.57 9940 .0432 .0529 576
Brant 397.5 24/7 .1287 .0858 .2574 .772 374 137 511 73.21 26.79 14600 .0430 .0526 584
Lbis 397.5 26/7 .1236 .0962 .2885 .783 374 172 546 68.51 31.49 16300 .0428 .0523 587
Lark 397.5 30/7 .1151 .1151 .3453 .806 375 247 622 60.35 39.65 20300 .0425 .0519 594
Pelican 477 18/1 .1628 .1628 .1628 .814 447 70 517 86.44 13.56 11800 .0360 .0442 646
Flicker 477 24/7 .141 .094 .2819 .846 449 164 614 73.21 26.79 17200 .0358 .0439 655
Hawk 477 26/7 .1354 .1053 .316 .858 449 207 656 68.51 31.49 19500 .0356 .0436 659
Hen 477 30/7 .1261 .1261 .3783 .883 450 296 746 60.35 39.65 23800 .0354 .0433 666
Osprey 556.5 18/1 .1758 .1758 .1758 .879 522 82 603 86.43 13.57 13700 .0308 .0379 711
Parakeet 556.5 24/7 .1523 .1015 .3045 .914 524 192 716 73.21 26.79 19800 .0307 .0376 721
Dove 556.5 26/7 .1463 .1138 .3413 .927 524 241 765 68.51 31.49 22600 .0306 .0375 726
Eagle 556.5 30/7 .1362 .1362 .4086 .953 525 345 871 60.35 39.65 27800 .0303 .0372 734
Peacock 605 24/7 .1588 .1059 .3177 .953 570 209 779 73.2 26.8 21600 .0282 .0346 760
Squab 605 26/7 .1525 .1186 .3559 .966 570 262 832 68.51 31.49 24300 .0281 .0345 765
Wood duck 605.0 30/7 .142 .142 .426 .994 571 375 946 60.35 39.65 28900 .0279 .0342 774
Teal 605.0 30/19 .142 .0852 .426 .994 571 367 939 60.86 39.14 30000 .0279 .0342 773
Kingbird 636 18/1 .188 .188 .188 .94 596 94 690 86.43 13.57 15700 .0270 .0332 773
Swift 636.0 36/1 .1329 .1329 .1329 .93 596 47 643 92.72 7.28 13690 .0271 .0334 769
Rook 636 24/7 .1628 .1085 .3256 .977 599 219 818 73.22 26.78 22600 .0268 .0330 784
Grosbeak 636 26/7 .1564 .1216 .3649 .991 599 275 874 68.51 31.49 25200 .0267 .0328 789
Scoter 636.0 30/7 .1456 .1456 .4368 1.019 600 395 995 60.35 39.65 30400 .0256 .0325 798
Egret 636 30/19 .1456 .0874 .4368 1.019 600 386 987 60.85 39.15 31500 .0266 .0326 798
Flamingo 666.6 24/7 .1667 .1111 .3333 1 628 230 858 73.21 26.79 23700 .0256 .0315 807
Gannet 666.6 26/7 .1601 .1245 .3736 1.014 628 289 916 68.51 31.49 26400 .0255 .0313 812
Stilt 715.5 24/7 .1727 .1151 .3453 1.036 674 247 920 73.21 26.79 25500 .0239 .0294 844
Starling 715.5 26/7 .1659 .129 .3871 1.051 674 310 984 68.51 31.49 28400 .0238 .0292 849
Redwing 715.5 30/19 .1544 .0927 .4633 1.081 676 435 1110 60.85 39.15 34600 .0236 .0290 859
Coot 795 36/1 .1486 .1486 .1486 1.04 745 58 804 92.72 7.28 16710 .0217 .0268 884
Drake 795 26/7 .1749 .136 .408 1.107 749 344 1093 68.51 31.49 31500 .0214 .0263 907
Tern 795 45/7 .1329 .0886 .2658 1.063 749 146 895 83.67 16.33 22100 .0216 .0269 887
Condor 795 54/7 .1213 .1213 .364 1.092 749 274 1023 73.21 26.79 28200 .0215 .0272 889
AAC/ACSR/AAAC/Aacsr Overhead Line Conductor-Bare Conductor
AAC/ACSR/AAAC/Aacsr Overhead Line Conductor-Bare Conductor
AAC/ACSR/AAAC/Aacsr Overhead Line Conductor-Bare Conductor
 

Commercial Heat Pump

Commercial Heat Pump,Ductless Heat Pump ,Heat Pump Thermostat ,Ductless Air Conditioner

Heat Pump Water Heater Co., Ltd. , http://www.nbheatpumps.com